Features about real-time pcr:
1.48 wells, which can realize high-throughput detection of multiple samples;
2.High efficiency of temperature control: temperature accuracy and module temperature control accuracy are ≤ 0.1 ℃, temperature uniformity is less than ± 0.1 ℃;
3.Two kinds of fluorescence detection modules can realize multiple detection of single sample;
4.Complete 2-color fluorescence scanning in 2 seconds, shorten your experiment time;
5.7 inch full color touch screen, intuitive operation, easy to learn;
6.High brightness maintenance free LED light source, without any calibration work after moving;
7.It has the function of power-off protection, and automatically continues to run after power on;
8.The software can be upgraded. After upgrading, it has HRM, SNP and other analysis functions.
Parameters about Real-time PCR:
|
Gentier 48E |
Gentier 48S |
Gentier 48R |
Thermal block |
Sample capacity(wells) |
48 |
Reaction volume |
5-100 μl |
Consumables |
0.2ml 8-strip tubes,0.2 PCR single tube(Optical flat cap,clear tube) |
Temperature range |
0.0 ~100.0ºC |
Heating/cooling method |
Peltier |
Maximum heating rate |
8.0ºC/s |
Average heating rate |
6.0ºC/s |
Maximum cooling rate |
5.5ºC/s |
Average cooling rate |
4.0ºC/s |
Temperature Accuracy |
±0.1 C |
Temperature uniformity |
±0.1 C |
Gradient Range |
1-40ºC |
N/A |
1-40ºC |
Gradient block |
8 row |
/ |
8 row |
Special temperature protocol |
Gradient PCR, long PCR,Touch Down PCR |
long PCR,Touch Down PCR |
Gradient PCR, long PCR,Touch Down PCR |
Heat lid |
Temperature range |
Room temperature-110 |
Optical system |
Excitation soure |
4 LEDs |
4 LEDs |
2 LEDs |
Detector |
Photodiode |
Detection position |
Excitation and scan from lateral |
Detection method |
4 channels scanning at the same time,no edge effect |
Detection time |
2 seconds for 48 wells for all channels |
Range of excitation/emission wavelengths(nm) |
1.465/510(FAM,SYBER Green I,SYTO9,EvaGreen,LC Green)
2.527/563(HEX,VIC,TET,JOE)
3.580*616(ROX,Texas Red)
4.632/664(Cy5) |
1.465/510(FAM,SYBER Green I,SYTO9,EvaGreen,LC Green)
2.527/563(HEX,VIC,TET,JOE)
3.580*616(ROX,Texas Red)
4.632/664(Cy5) |
1.465/510(FAM,SYBER Green I,SYTO9,EvaGreen,LC Green)
2.527/563(HEX,VIC,TET,JOE) |
Probe |
Taqman Probe,Molecular beacons probe,Scorpion probe |
Multiplexing |
Up to 4 targets |
Up to 4 targets |
Up to 2 targets |
Fluorescence linearity |
r≥0.990 |
Fluorescence Dynamic range |
Adjustable |
Performance |
Sample linearity |
r≥0.999 |
Sample repeatability |
Ct value CV≤0.5% |
Sample Dynamic range |
1-1010copies |
Software function |
Data analysis modes |
Qualitative analysis,absolute quantification,relative quantification,genotyping analysis,endpoint analysis,melt curve analysis,high resolution melting |
Control modes |
1.7 touch screen
2.PC direct control
3.WLAN control(one PC can control max 10 units,and device can be controlled by any PC in the WLAN) |
Data storage |
Upload and download through USD disk,1000 results can be stored in machine |
Power failure protection |
Automaticly start running experiments after power supply,no need wait PC software |
Customize report |
Templetes reserved,report can customized |
Administration management |
Administrator can set functions limits for users |
Fault management |
Fault report and analysis,solution instruction |
LIS connection |
CSV,Excel,TXT format data output,open port for LIS connection |
others |
PC operation system |
Windows 7,Windows 10 |
Communication port |
1 thernet and 2 USB |
Footprint(W*D*H) |
260*400*260mm |
Weight |
11kg |
Power usage |
AC 100 to 125V/200 to 240V(50/60HZ) |
Power consumption |
600VA |
Work environment |
Temperature:10ºC-30ºC humidity:20%-85% |